Description

Trim, Rack-Mountable Design:
  • Dimensions: 5 1/2in h x 19in w x 8 1/4in d
  • Weight: 9.1kg (20lb)

Variable, Protected Power:
  • 110V input voltage
  • >240VAC / 220VDC ouput voltage
  • >5Amp output current, protected by a resetable breaker
  • Output power is precisely set using a Variac dial
  • Analog Voltage and Amperage meters provide visual confirmation of the Variac setting

Designed for Flexibility:
Three toggle switches allow selection of:
  • AC or DC firing
  • Positive or negative phase operation
  • Line 1 or Line 2, to connect two drums of wireline, for example.

Five jacks - DAS, AUX, CCL, SAFE, and FIRE - allow you to:
  • 'Dual' track the CCL markers by recording with the DAS and visually/audibly
  • tracking with the shooting panel.
  • Use the unit as an auxillary patch panel, or add a second system, via the AUX jack.
  • The analog CCL meter and the unit's audible signal make CCL logging simple. Gain
  • and volume are adjustable.
  • Prevent stray voltage by grounding with the SAFE jack.
  • Avoid accidental firing; the FIRE jack must be connected in order to fire.

Features

Safety is a key design consideration:
The unit must be unlocked and in the fire position, with the Variac dial off, before firing can take place.

Firing requires two-handed operation:
  • The left hand lifts the switch guard and the firing toggle.
  • The right hand dials up the power supplied to the wireline. The voltage andamps can be observed in the meters. The panel will not fire again until the
Variac is dialed down and the steps repeated.

For additional safety, an external safety line lockout is available by special order.