Description
Dimensions and Weight
Overall Length: 1.83m 6.01ft
Overall Weight: 25.7lb 17.2kg
Diameter: 41.3mm 1 5/8in
Borehole Characteristics
Borehole Fluids:
Oil
Fresh or Salt Water
Logging Speed:
9 m/min
30 ft/min
Tool Positioning:
Centralized operation
Eccentralized operation
Environmental
Maximum Well-Bore Temperature:
175°C / 350°F
Maximum Well-Bore Pressure:
112MPa / 18000psi
Detection
Scintillation crystal/PMT Gamma Ray detector, temperature-rated to 135°C / 275°F or 175°C / 350°F
Measurement
Outputs:
CCL, Gamma Ray
Output Format:
Pulses
Reference Point:
CCL (25cm below the top of the tool)
Offsets*:
Gamma Ray 'A': 60cm below CCL
Gamma Ray 'B': 138cm below CCL
Detector: 255cm below CCL
* Orientation-dependent. Typically run with electronics in position
'B'. To run with a Neutron Detector, re-orient to position 'A'.
Operational
Current, CCL: 15mA
Current, Gamma Ray: 35mA
Cable Head Voltage: 80VDC
Shock Voltage Protection: 200VDC
Selectable Pulse Output Polarity
Features